SEO – Phoenix 150/300 Manual Contact Angle Analyzer

Phoenix-150/300 Brochure

Overview

The Phoenix series is designed to offer the flexibility required for QA, R&D and engineering development

The Phoenix series has a specially designed optical system for reducing the light scattering and is mounted with a camera easily adjusted in all directions.  The fluids are dispensed from a manually controlled syringe system or semi auto/automatically by embedded a stepping motor system.  The position of the sample stage can be precisely adjusted along the X, Y or Z-axis for fine image analysis

Features

  • Manual and rapid sample analysis and high-speed dynamic image capture
  • Improved precision and reproducibility by the elimination of operator error
  • Available to connect to notebook or desktop PC via USB port
  • Auto calculation of surface energy and work of adhesion
  • High resolution and powerful image capture system
  • Automatic & manual image analysis

Typical Application

  • Semiconductor applications
  • Detection of organic contamination on PCB and electronic components
  • Evaluation of cleanliness / treatment / coating processing
  • Hydrophobicity and hydrophilicity of solid surfaces
  • Biological application such as the detection and characterization of proteins
  • Adsorption / Wettability of powder and pharmaceutical products1.Static Contact angle measurement Measurement range : 0~180°  

    2. Easy Surface Energy calculator (GGFY, Owens Wendt, Lewis method)

    Using measured contact angle data itself

    3. Surface tension by pendent drop method

    (1mN/m ~ 1000nM/m)

    4. Curved surface sample measuring function

     

    Software function

     1. Static contact angle calculation by three modes

       - Tangent line method 1(For Tilting contact angle and bigger drop volume)

       - Tangent line method 2(For common measurement)

       - Trigonometric function (For low angle measurement : less than 30degree)

    2. Realtime Preview Result before capture function

    - Able to check condition of image before capture - Measurement data will be display before capture

    - Able to check an instant contact angle and surface tension data

    3. Manual mode for critical sample 

    4. Auto calculate average

    - Automatic calculation of the average contact angle data by the software based on the frames captured.

    5. Graphical data

    6. Four types of capture modes

    •    Single mode -  One by one capture image
    •    Sequence mode -  Able to check by interval time base
    •    Verify mode -   Will show only one Maximum frequent image
    •    Programmed mode - Use it with Tilting, Time base by triggering

    7. Export captured date to Excel (2 modes)

    •    Selected only one image export on whole measured image

    • All images export at once into an collection

    8. Manual define Base line  function

    •  User can define the baseline manually for difficult to calculate contact angle

    Analysis of plasma treatment to increase the wettability of polymers surfaces

Model Phoenix 150
Max. Sample Size ( mm) 200 x 50 mm(H) x∞(D)
Contact angle range 0° - 180°
Accuracy +/- 0.1°
Dispense Control Manual for PC control & manual by precise screw
Light Source White LED module
Lens Zoom Lens 12x
Frame Rate 70FPS
Operating System Window7,8,10
Power 110 / 220 Volt 50/60 Hz
Dimension ( LxWxH, mm)  (620 x 260 x 500 mm)