Bettersizer ST Laser Particle Size Analyzer

Introduction of Bettersizer ST

Bettersize General Brochure

Bettersizer ST is an intelligent dual lenses particle size analyzer with integrated design, and all of the operations can be completed automatically under the control of the computer. It has particular functions included auto test, auto alignment, auto water supply, auto drainage, auto bubble removing, auto cleaning and other automated routines. The use of high performance semiconductor laser provides a life time over 25000 hours. The use of anti-dry ultrasonic dispersing technology ensures when opening ultrasonic, the instrument will not be damaged when circulating tank without water. The instrument has outstanding accuracy and good reliability, good repeatability, easy operating, fast test speed, etc. It is a new generation of particle size analyzer that integrates the technologies of laser, computer and photoelectron, and especially suits the laboratories of enterprises, universities and research institutes to use.

Repeatability

Excellent repeatability is achieved thanks to:

- Laser, detector and signal transmission system are stable and reliable.

- Consistent and effective dispersing system.

- Automatic alignment keeps the instrument always in optimum condition.

- Sampling rate up to 3500 times/second ensures outstanding repeatability

Repeatability verification:

a) Repeatability of a serial test for same samples

About Repeatability

Repeatability is primary index of particle size analyzer. It is worthless for particle size analyzer if repeatability is not good. Repeatability is related to the instrument, also, related to the operator, voltage, water quality and interference. It is a reflection of integrated factors.

b) Repeatability of re-sampling test

Accuracy

Excellent accuracy is achieved thanks to:

- The use of a dual lenses optical system (DLOS) invented by Bettersize, it improves the precision of the analysis compared to single lenses systems.

- The use of 86 detectors plus high performance software, provides excellent resolution regardless the sample has a single modal or multimodal distribution.

- Complete sample preparation system including circulation, ultrasonic dispersing, stirring, auto water supply and auto cleaning.

- Use of size standard to verify the accuracy of the results.

Verifications of accuracy:

a) Accuracy which approved by China National Accreditation: Satisfactory.

b) Compare with test results of other brand

CaCo3 D10 D50 D90 Fluorescent Powder D10 D50 D90
Other brand 0.752 2.117 5.576 Other brand 11.108 24.017 44.638
Bettersizer ST 0.755 2.055 5.47 Bettersizer ST 10.6 23.79 44.68

c) Use Bettersize standard to verify accuracy

Reliable performance and easy operation

 Reliable performance is achieved thanks to:

- Use of high quality components.

- Components are inspected and recorded for traceability. A 48-hour failure test before instruments leaves the factory.

- Use of advanced technologies such as dry burning-resistant ultrasonic, auto alignment, dew-point temperature detecting and others

- Comply with CE, FDA 21 CFR Part 11 and ISO 9001-2008 certification.

Easy operation:

Just adding the sample, the system will automatically perform the analysis, including routines as water supply, dispersion, circulation, concentration adjustment, test, draining, cleaning, print report and saving data. If the concentration is high, the system will dilute automatically. If the concentration is low, the system will show “add sample”, to guarantee that the concentration always is at an adequate level. The complete automation is not only for easy of use, more importantly, it reduces the errors caused by human factors and providing consistent results.

Unique technology for reliable quality

Dual lenses optical system (DLOS):

Dual lenses optical system (DLOS) is a patented technology invented by Bettersize. Dual lenses optical system (DLOS) integrates forward, lateral and backward scattering; detection quantity of scattered lights will be doubled. Compare with single lens laser particle size analyzer, it improves detection range, test precision for fine particles and resolution. Compare with dual beam particle size analyzer, it improves performance reliability.

Auto alignment technology:

The auto alignment system invented by Bettersize is composed of stepping motor, precise guide rail, subdivision controller and software system. The minimum step is 1.3 micron, which ensures that the focus of laser beam always irradiates the center of the detector and improves the accuracy of the result.

Ingenious accuracy calibration technology:

All of the instruments have passed the calibration of standard sample, which fully ensures that the accuracy of test results. Meanwhile, provide standard sample with the instrument to the customer and users can verify the accuracy of the instrument at any time, to avoid the losses from inaccurate test results because of instrument drifting and voltage fluctuation.

 

 

Reliable circulating and dispersing system:

The liquid circulating and dispersing system of Bettersizer S2 includes anti-dry ultrasonic disperser, centrifugal circulating pump, auto supply water system, auto drainage and overflow preventing system.

Example of report (more than 14 report formats available)

Specification

Testing parameter Material
Particle size distribution Suspension, emulsion, dry powder
General Bettersizer 9300ST
Theory Laser diffraction
Analysis theory Mie and Fraunhofer
Testing speed 3kHz
Typical measurement time ≤10 second
Size
Size range 0.1 - 1000um
Number of size classes More than 100 customized grades
Accuracy ≤1% (GBRM D50)
Repeatability ≤1% (GBRM D50)
Resolution ratio Single peak, double peak, multi-peak
Optics
Red light Max. 3mW, Semiconductor optical fiber laser, 635nm
Lens arrangement Dual lenses on the right and left of sample cell
Lens design F-Theta Lenses
Effective focal length 223mm
Detector
Arrangement Log-spaced array
Quantity 86 pieces (forward, sideway, backward)
Light path adjustment Intelligent automatic alignment
Sample dispersion system
Dispersion type Wet
Dispersion system Ultrasound 50W, 38 KHz

Dry burning-resistant protection system

Water circulation Centrifugal pump, 500 -2500 ml/min,

auto water intake and rinsing

Water capacity 600 ml
Software
21 CFR Part 11 Enable
SOP Designer Enable
Report More then 14 formats report
Auto test Enable
Data export EXCEL, PDF,WORD, JPG and etc.
System compliance
Laser class Class I laser product
System
Supply voltage 220VAC
Dimension 660mm x420mm x 320mm (L x W x H)
Weight 38kg
Computer specification
Computer interface At least a USB2.0 port required
Operation system Windows XP,  Windows 7,8 or 10
Hardware specification Intel Core I5, 4GB RAM, 250GB HD

ication