Bettersizer S2-G Laser Particle Size Analyzer

Introduction of Bettersier S2-G

Bettersize General Brochure

Bettersizer S2-G is an intelligent particle size analyzer that adopts 400nm short wavelength laser as light source, lower limit of test can reach to 0.01μm, and has particular functions of auto test, auto alignment, auto water supply, auto bubble removing, auto cleaning and other automated routines. The use of high precision lenses with clear imag and low distortion, ensures that weak scattered light signals produced from particles in submicron, even in nanometer can be received effectively. It adopts anti-dry dispersing technology, when turn on ultrasonic, circulation tank will not be damaged without water. The instrument has the characteristics of accuracy and good reliability, good repeatability, easy operating, fast test speed etc., which especially suits mixed sample in micron and nanometer

Repeatability

Excellent repeatability is achieved thanks to:

- Laser, detector and signal transmission system are stable and reliable.

- Consistent and effective dispersing system.

- Automatic alignment keeps the instrument always in optimum condition.

- Sampling rate up to 3500 times/second ensures outstanding repeatability

- High precision lenses with clear image and low distortion, ensures that weak scattered light signals and

light signals from various angles can be completely detected.

Repeatability verification:

a) Repeatability of a serial test for same samples

About Repeatability

Repeatability is primary index of particle size analyzer. It is worthless for particle size analyzer if repeatability is not good. Repeatability is related to the instrument, also, related to the operator, voltage, water quality and interference. It is a reflection of integrated factors.

b) Repeatability of re-sampling test

Accuracy

Excellent accuracy is achieved thanks to:

- The use of a dual lenses optical system (DLOS) invented by Bettersize, it improves the precision of the analysis compared to single lenses systems.

- The use of green light laser that wave length is 532nm plus high performance software, provides excellent resolution regardless the sample has a single modal or multimodal distribution.

- Complete sample preparation system including circulation, ultrasonic dispersing, stirring, auto water supply and auto cleaning.

- Use of size standard to verify the accuracy of the results.

Verifications of accuracy:

a) Accuracy which approved by China National Accreditation: Satisfactory

b) Test results of standard sample in nanometer: Deviation to the nominal value is very small.

Standard sample D50 (nm) 27.33 62.11 100 600 800
Bettersizer S2-G 27.57 61.55 101.23 595.11 822.11

Reliable performance and easy operation

 Reliable performance is achieved thanks to:

 - Use of high quality components.

- Components are inspected and recorded for traceability. A 48-hour failure test before instruments leaves the factory.

- Use of advanced technologies such as dry burning-resistant ultrasonic, auto alignment, dew-point temperature detecting and others

- Comply with CE, FDA 21 CFR Part 11 and ISO 9001-2008 certification.

Easy operation:

Just adding the sample, the system will automatically perform the analysis, including routines as water supply, dispersion, circulation, concentration adjustment, test, draining, cleaning, print report and saving data. If the concentration is high, the system will dilute automatically. If the concentration is low, the system will show “add sample”, to guarantee that the concentration always is at an adequate level. The complete automation is not only for easy of use, more importantly, it reduces the errors caused by human factors and providing consistent results.

Unique technology for reliable quality

Dual lenses optical system (DLOS):

Dual lenses optical system (DLOS) is a patented technology invented by Bettersize, with green light source, and detection quantity of scattered lights for particles in nanometer increase 5 times which expends lower limit of the test. It promotes test range, test precision of particles in nanometer and resolution

Auto alignment technology:

The auto alignment system invented by Bettersize is composed of stepping motor, precise guide rail, subdivision controller and software system. The minimum step is 1.3 micron, which ensures that the focus of laser beam always irradiates the center of the detector and improves the accuracy of the result.

Powerful software:

Use of Mie scattering theory and free mode inversion algorithm to obtain accurate particle size distribution. Use of the exclusive “project” concept to save results and multi-language function to easily change languages. The software provides safety management function, when enabled, the use of password is required to login into the software.

Reliable circulating and dispersing system:

The liquid circulating and dispersing system of Bettersizer S2 includes anti-dry ultrasonic disperser, centrifugal circulating pump, auto supply water system, auto drainage and overflow preventing system.

Example of report (more than 14 report formats available)

Specification

Testing parameter Material
Particle size distribution Suspension, emulsion, dry powder
General Bettersizer S2-G
Theory Laser diffraction
Analysis theory Mie and Fraunhofer
Testing speed 3kHz
Typical measurement time ≤10 second
Size  
Size range 0.01 - 800um
Number of size classes More than 100 customized grades
Accuracy ≤0.5% (GBRM D50)
Repeatability ≤0.5% (GBRM D50)
Resolution ratio Single peak, double peak, multi-peak
Optics  
Green light source Max.5mW, Semiconductor optical fiber laser, 532nm
Lens arrangement Dual lenses on the right and left of sample cell
Lens design F-Theta Lenses
Effective focal length 223mm
Detector  
Arrangement Log-spaced array
Quantity 90 pieces (forward, sideway, backward)
Light path adjustment Intelligent automatic alignment
Sample dispersion system  
Dispersion type Wet
Dispersion system Ultrasound 50W, 38 KHz

Dry burning-resistant protection system

Water circulation Centrifugal pump, 500 -2500 ml/min,

auto water intake and rinsing

Water capacity 600 ml
Software  
21 CFR Part 11 Enable
SOP Designer Enable
Report More then 14 formats report
Auto test Enable
Data export EXCEL, PDF,WORD, JPG and etc.
System compliance  
Laser class Class I laser product
System  
Supply voltage 220VAC
Dimension 800mm x 500mm x 410mm (L x W x H)
Weight 45kg
Computer specification  
Computer interface At least a USB2.0 port required
Operation system Windows XP,  Windows 7,8 or 10
Hardware specification Intel Core I5, 4GB RAM, 250GB HD